The Digital Scout is the latest advancement in hand-held test equipment by Optoelectronics, Inc. The Digital Scout is the first nearfield device capable of detecting digital RF. The Digital Scout is able to detectdigitalsignalswithaminimumpulsewidthof300uS.
Reaction Tuning the Icom IC-R10 with the Optoelectronics Scout Model 40 - Duration: 4:02. Learn Science by doing. ANDREā¢ - Near-Field Detection Reciever - Duration: 1:48.
Scout 10MHz-1.4GHz RF counter and Reaction Tuner. Optoelectronics, Inc. 885 Woodstock Rd Ste. #430-521 Roswell, GA 30075. Tel: 954-642-8997 Fax: 954-636-3533.
The Digital Scout also incorporates the Optoelectronics patented, Reaction Tune and the built-in RS232 port allows for the direct connection to a PC for real time datalogging and download of frequencies in memory. Another breakthrough feature of the Digital Scout is the calibrated field strength measurement provided on the two line LCD display.
Below are some of the Optoelectronics Inc. Product manuals. Most files are in PDF, while a few are Word documents. If you do not see the manual you are looking for then chances are we do not have a copy available. Please call us at 954-642-8997 to ask about availability.
Howdo, Anyone used a Opto Digital scout (10 mhz-2.6 ghz).!with or without reaction tuning the Scanner,with it.!
Optoelectronics
Will it capture 'Digital modulation' as well as conventional analogue.does any folk know? i.e.RF from macrocells ,2.4ghz cctv,etc. Is it similar to 'close call' on a modern radio scanner , in any way ? Just a query .!always thought of investing in one,not anymore though seeing as the radio signals round my vicinity are dull and pretty much all 'digital & data' .to say the least, living in a small community with lot'sa hilly terrain. Bye
A NEW SCOUT FOR THE DIGITAL AGE
Digital Scout
Rechtstreeks uit Amerika, vandaar nog geenNederlandse vertaling beschikbaar, dit apparaat betekent werkelijk een doorbraak op hetgebied van frekwentie opsporing en detectie ! Lees hieronder in het Engels verder of komlangs voor een uitgebreide demonstratie ( neem uw GSM telefoon mee )
The new Digital Scout RF frequency recorder / field strength meter isthe only nearfield instrument capable of counting digitalsignals, as well as analog signals from 10MHz - 2.6GHz. Until now, the only signals that afrequency counter could lock onto were analog signals. In addition to locking onto digitaland analog signals, the Digital Scout has a calibrated signal strength measurement from-45dBm to -5dBm.
DIGITAL MODULATIONS
The Digital Scout is capable of detecting many different types ofdigital modulations that have a minimum pulse width of 500uS, signals such as TDMA, GSM,APCO 25, ON/OFF Keying, TETRA and more.
The Digital Scout is not capable of counting signals such as SpreadSpectrum, CDMA and PCS.
SIGNAL STRENGTH
Optoelectronics Inc
Another breakthrough feature of the Digital Scout is the calibratedfield strength measurement provided on the two line LCD display. The Digital Scoutdisplays field strength in dBm with a signal strength bargraph serving as a reference. TheDigital Scout reads and displays signal levels from -45dBm to -5dBm with an accuracy of+/- 5dBm. This feature is great for checking nearfield RF levels at remote sites, locatinghidden transmitters, determining power levels from two-way radios and more.
REACTION TUNE
The Digital Scout incorporates the patented Optoelectronics feature,Reaction Tune. In Reaction Tune mode the Digital Scout captures a frequency andautomatically tunes a compatible receiver to that frequency. This allows the user toinstantly monitor the audio of the captured signal (analog signals only). Those receiverscompatible with the Digital Scout for Reaction Tune are as follows.
ICOM IC R10, R7000, R7100, R8500, R9000. AOR AR8000 and AR8200. BC245XLTand BC780. OPTOELECTRONICS Optocom, Os456/Lite, OS535 and R11
All ICOM: CBCI5, AORAR8000: RT8000, AOR AR8200:RT8200, BC245XLT/BC780: (SmartLink from Scannermaster), OPTOELECTRONICSOptocom/OS456/Lite/OS535: CBCI5, R11: CBRT
PC INTERFACE
The Digital Scout has a built-in CI-5 interface that can be used tointerface to the Optoelectronics Optolinx for downloading frequencies saved to memory.This interface allows for direct connection to the Optolinx which in turn interfacesdirectly to serial port on a PC.
ADDITIONAL FEATURES
The Digital Scout has a unique way of displaying the frequency measured.Like most conventional frequency counters, the Digital Scout will display the actualmeasured frequency coming from a transmitter, such as 454.1247. However, the Digital Scoutcan also display the actual channel frequency of the transmitter, such as 454.1250. Thisis especially useful to the two way radio professional when programming new radios.
The Digital Scout has 1000 memories with up to 65,000 hits per memory.Memory can then be downloaded directly to a PC using the Optolinx interface.
Single frequency range from 10MHz-2.6GHz.
Beeper and Vibrator alert
10MHz - 2.6GHz frequency range
5-6 hour battery operation
2x16 alphanumeric LCD with EL backlight
Signal Strength reading displayed in dBm and bargraph -45dBm to -5dBm
+/- 5dBm signal strength accuracy
Download memory to a PC using the optional Optolinx interface
Reaction Tune analog signals with ICOM IC R10, R7000, R7100, R8500 and R9000. AOR AR8000 and AR8200. Optoelectronics Optocom, OS456/Lite, OS535 and R11. BC245XLT and BC780 (SmartLink cable required)
1000 memories with 65,000 hits per memory
Captures both Digital (Minimum 500uS RF pulse required) and Analog signals
Beeper and Vibrator alert
Super Sensitive, down to 700uV in some bands
Frequency Range
10MHz to 2.6GHz
Resolution
1KHz and 100Hz
Frequency Accuracy
1ppm
Signal Strength
-45dBm to -5dBm
Signal Accuracy
+/- 5dBm
Power
9VDC, 150mA using model AC90 wall plug adapter.
Size
5.25' H x 3' W x 1.5' D Weight 12oz
Display
2x16 alphanumeric LCD with EL backlight